Replacement gas/electric fire for a baxi back boil

Nov 26, 2012· southerngrumpy. Nov 24, 2012. #1. I have a Baxi back boiler which incorporates a Baxi Bermuda Gas fire. The gas fire is faulty but Baxi no longer make a replacement and suggest that I replace the back boiler and incorporate a Valor electric fire. The total cost of replacement including flue and labour is estimated at around 4k.

Back Boiler Replacement – Prices, Costs and Upgra

Baxi are the creators of the original Bermuda Back Boilers and are the only brand of boiler to release a modern condensing boilers back boiler. The new Baxi Bermuda BBU HE is more efficient and has a SEDBUK A efficiency rating. It has a 15KW heat output and has a room sealed appliance removing the need for air vents. The Baxi Bermuda BBU HE is

What is a Back Boiler? | Ba

Back boilers (also known as back boiler units or BBUs) became popular in 1966 with the launch of the original Baxi Bermuda. A back boiler is a small, compact boiler fitted at the back of an open fireplace hearth. It sits behind a gas fire and provides hot water and central heating to the property.

What fire front can I get to go on an old Back boil

Good luck with the fire, we also have a back boiler and a very early 90s fire which is gopping. Looked at replacing it and the only one we could find was about £800. As back boilers haven't been used for a while it's a very specialist market. For us we are waiting until the boiler dies and then will replace when a combi boiler goes in.

BAXI bermuda back boiler - time to upgrade ? | DIYnot Foru

Dec 07, 2019· We have a BAXI bermuda back boiler and fireplace, with a hot water cylinder in the airing cupboard and cold and expansion tanks in the loft. Me and my wife discussed about changing the boiler, but at the time we decided that we would keep it as it seems to be working fine (for the most part!), and so we purchasd an electric shower to go in the

Immediately Dangerous Back Boiler Part 2 Baxi Bermuda 55

Aug 08, 2014· But I was wrong!, when I looked under the gas fire ( remember this is a back boiler with the gas fire in the front) I was shocked to see this. I immediately closed the switch off the boiler and

Baxi Bermuda Spares for sale in UK | View 32 bargai

Baxi combi 80e 80eco 105e 105he 3 way diverter. Baxi bermuda vp gas fire to fit on back boiler ideal replacement for baxi c5 ,c5w, or use for spares. baxi bermuda back boiler , and front fire baxi bermuda gf3 super , excellent used bcondition . baxi bermuda back boiler , plus front fire baxi bermuda gf3 super , in excellent used bcondition .

Baxi Bermuda BBU HE - Boilers Pric

The Baxi Bermuda HE is a fully condensing back boiler with a 15 KW heat output. Key features include a SEDBUK A rating for maximum fuel efficiency, and it is flexible enough to be used with both open vent and sealed systems. It also has a lightweight cast alloy heat exchanger …

New fire for a back boiler — MoneySavingExpert For

Aug 11, 2009· depends on make and model of bbu, if you have a baxi, for example 551/552 there are many fire fronts available that are compatible, best one probably the vp if you have a hearth and surround or the sp if its wall mounted, they are bloody expensive to buy new but are available second hand as they need to be taken out/ shut off if the back boiler is decommisioned to fit a combi etc.

Baxi Bermuda 51/5 Back Boiler | PlumbersForums.n

Feb 03, 2013· Old baxi bermuda to combi boiler cost help! Central Heating Forum: 11: Dec 1, 2019: J: Baxi Bermuda inset 3 boiler 50/5 PCB problem: Gas Engineers Forum: 11: Dec 8, 2017: U: Baxi Bermuda condensing boiler: Central Heating Forum: 1: Mar 11, 2016: S: Baxi Bermuda 551 Back Boiler problem. Central Heating Forum: 10: Oct 18, 2015: J: baxi bermuda

Baxi Bermuda Back Boiler | Screwfix Community For

Oct 31, 2018· Baxi Bermuda Back Boiler. Discussion in 'Plumbers' Talk' started by Lizd, Oct 31, 2018 When it fires up on its own it does not open up the motorized values so don't think its a programmer problem but just to eliminate this I have had the programmer replaced and last year I had the motorized value on the heating replaced as it was sticking


Need more information?

Contact us for more details about our boilers, solutions and services.

Online message


Gas-fired(oil-fired) boilers
Coal-fired boilers
Biomass-fired boilers
Thermal oil heaters
Hot water:0.7-14 MW
14.1-21 MW
21.1-29 MW
29.1-75 MW
Steam :  1-10 t/h
11-20 t/h
21-90 t/h
91-140 t/h
Contact us
Tel

0086-510-68530066

Chat online