product

Your Current Location: Home | spirax sarco low pressure steam boiler 15 psi

spirax sarco low pressure steam boiler 15 psi

Online message

BCV1 and BCV20 Blowdown Valves - Spirax Sar

Maximum boiler or steam pressure - Intermittent operation: 14 bar g 203 psi g: 4 bar g 58 psi g: Medium temperature range-0 to +200 4 °C -0 to +392 4 Solenoid valves shall be Spirax Sarco normally closed, low pressure blowdown valve type BCV20 with brass bodies and stainless steel

Condensate Return and Boiler Feed Pumps “G” Seri

Spirax Sarco "G" Series condensate and boiler feed pumps are packaged units com-pletely assembled, wired and tested at the factory. They are used in low pressure steam heating systems to collect and quickly return condensate to the boiler or boiler Simplex unit 6,15, 21 and 45 gallon sizes. Duplex unit 15, 21 and 45 gallon sizes. Welded

Pressure Reducing Valves for Heating & Cooling Applicatio

Spirax-Sarco model SRV461 stainless steel direct operated pressure regulator with a 1-1/4" NPT connection for 4-16 psi service. The SRV461 features a non-rising adjustment screw, an o-ring soft seal on the valve plug for tight shutoff, and 316 Ti stainless steel construction of the wetted parts.

Spirax-Sarco Float and Thermostatic Steam Traps f

Spirax-Sarco F&T traps feature an H pattern piping style which has an inlet and an outlet connection on both sides of the trap, allowing for more piping-in choices. They are available in pipe sizes from 3/4" to 2" and steam operating pressures from 15 to 200 psi.

Balanced Pressure Steam Traps | US | Spirax Sar

Spirax Sarco Balanced Pressure Thermostatic Steam Traps automatically adjust to varying steam pressures and its robust design reduces plant maintenance costs. Boiler Controls and Systems You will now continue to the existing site for Spirax Sarco .

Steam Pressure Reducing Valves | Cooney Brothe

Shop Spirax Sarco steam pressure reducing valves from an authorized Spirax Sarco distributor. Cooney Brothers stocks a wide range of Spirax Sarco 25P, BRV2S, SRV2S and more - the valves you need to run your steam system efficiently. View full specs and buy Spirax Sarco steam …

Boiler Controls and Systems | US | Spirax Sar

During formation in the boiler, steam leaves behind impurities (TDS - total dissolved solids). If left these concentrate and cause damage to the boiler. Vent Heads. Fitted to the top of a vent pipe, dissipates the velocity of vapour ejected to atmosphere. You will now continue to the existing site for Spirax Sarco .

BDV60 Blowdown Vessels - Spirax Sarco | First for Ste

If the length is less than 7 m multiply the actual boiler pressure by 1.15 before using the sizing table, Table 2. The blowdown regime:-Typical normal bottom blowdown of, perhaps, 5 seconds duration.-Weekly low level alarm testing where practice is in accordance with BG01 and INDG436 - steam down from normal level to first low

Steam Boilers - The Inside Story: Part 5 - Low Pressu

Mar 13, 2014· 9 videos Play all Steam Boilers - The Inside Story Spirax Sarco; How to Low pressure gauge 0-3 psi on steam boiler after 45 minute burn - Duration: 15:19. Armstrong

Apollo Valve 13-510 Series Bronze Safety Relief Val

This Apollo Valve 13-510 series steam relief valve is a safety valve for protecting small to medium low-pressure steam heating boilers. It has a cast bronze body, a 15 pounds per square inch (psi) relief pressure, a 3/4" male National Pipe Thread (NPT) inlet connection and 3/4" female NPT outlet, and a PTFE (polytetrafluoroethylene) seat.

DCV1, DCV3 and DCV3LT Disc Check Valves - Spirax Sar

Maximum operating pressure for saturated steam service 13.2 bar g @ 196 °C (191 psi g @ 355 °F) TMO Maximum operating temperature 260 °C @ 7 bar g (500 °F @ 101 psi g) Minimum operating temperature Note: For lower operating temperatures consult Spirax Sarco-198 °C (-324 °F) Temperature limits Viton seat -25 °C to +205 °C (-13 °F to 401


Need more information?

Contact us for more details about our boilers, solutions and services.

Online message


Gas-fired(oil-fired) boilers
Coal-fired boilers
Biomass-fired boilers
Thermal oil heaters
Hot water:0.7-14 MW
14.1-21 MW
21.1-29 MW
29.1-75 MW
Steam :  1-10 t/h
11-20 t/h
21-90 t/h
91-140 t/h
Contact us
Tel

0086-510-68530066

Chat online